Concert sound-level measurement and response log

Record the audience reference position separately from the long-term meter position, then track rolling 15-minute readings, output adjustments and audience protection through one event.

WHAT THIS TEMPLATE HELPS YOU PREPARE

A joined record of measurement positions, correction and calibration evidence, live sound levels and response times.

File formats
English XLSX · CSV (UTF-8)
Version
2.0
Editorial review
29 Oct 2026
Use this for
Use during commissioning, rehearsal, live operation and closeout of a show with amplified music. The fictional example is for an adult audience.

When to use it

Use during commissioning, rehearsal, live operation and closeout of a show with amplified music. The fictional example is for an adult audience.

WHO’s 100 dB LAeq,15min is an international recommended upper limit at the audience reference position, not a Korean statutory limit or a safety guarantee. Children-focused events need a lower limit. Transcribe the meter’s rolling average for the preceding 15 minutes; this sheet does not calculate sound level or corrections.

Start with the guide: Concert sound-level checks and audience hearing protection

Fill in the template step by step

When to use it

Use when requesting the audio measurement plan before commissioning, checking positions and correction in rehearsal, and logging live readings and actions.

What to have ready

  • Programme, run times, audience and loudspeaker layout
  • Venue contract sound conditions and the outcome of checking applicable Korean requirements
  • Meter and calibration records, plus the basis for any difference between reference and FOH readings
  • Original meter log and audience-protection plan
  1. The organiser sends programme, audience layout and run times to the audio lead and requests named reference and meter positions and operators.

  2. At rehearsal, the audio lead checks calibration and the relationship between the two positions, then records the correction method and evidence ID.

  3. During the show, transcribe the meter’s reference-position LAeq,15min rolling average and its time. If it approaches or exceeds the agreed operating ceiling, record who adjusted what, when, and the recheck.

  4. Explain earplug use and the quiet area to the audience. At closeout, pass the original log and intervention/recheck record to the operations lead.

Worked example

Fictional example, not an actual event or supplier record

Eight columns · scroll horizontally to view the complete worked example.

Concert sound-level measurement and response log — fictional worked example
Stage, time, programme, audience layout and run-time sourceAudience reference measurement positionLong-term meter position, device, calibration and correction evidenceEvent operating ceiling (dB LAeq,15min)Rolling average at reference position (dB LAeq,15min)Monitoring and output adjustment, action and recheckEarplugs and quiet-area informationStatus, open check, owner and deadline
Plan / 2026-11-08 15:00 Fictional adult-audience show, 2026-11-09 19:00–20:30 / programme P01 and layout L01Proposed centre R1 of the core audience area; rehearsal check pendingMeter: FOH balcony planned / calibration record for SLM-01 not received Correction: Difference between FOH and R1 not yet confirmed——Operators: Ask audio lead Kim to assign monitoring and output-adjustment operators Action and recheck: Organiser Lee sent P01 and L01 to Kim at 15:00Earplug point and quiet area not yet setOn hold. Kim to return position, calibration, correction and operator plan by 2026-11-08 17:00
Rehearsal / 2026-11-08 17:30 Programme P01 and layout L01 / 2026-11-09 19:00–20:30R1 at the centre of the core audience area on L01 confirmedMeter: SLM-01 at FOH balcony / on-site calibration check CAL01 at 17:10 Correction: Compared R1 with FOH, then applied a meter correction / audio lead review COR01 at 17:2096—Operators: Kim monitors and logs the display; Park adjusts output Action and recheck: Kim checked corrected display and LOG01 recording at 17:32Earplugs and use instructions at entry from 2026-11-09 18:30; lobby quiet area / front-of-house lead LeeFictional operating plan checked. Operations lead Choi to verify positions and information by 18:00
Show / 2026-11-09 19:30 Programme P01 and layout L01 / audience presentR1 on layout L01Meter: SLM-01 at FOH balcony / CAL01 checked Correction: Automatic COR01 correction applied; display represents R19696.3Operators: Kim reads LOG01; Park adjusts output Action and recheck: Park reduced main output at 19:31. Kim to recheck the rolling average at 19:45Entry earplugs with use instructions and lobby quiet area available / LeeAwaiting recheck after action. Kim to check LOG01 by 19:45
Show / 2026-11-09 19:45 Programme P01 and layout L01 / audience presentR1 on layout L01Meter: SLM-01 at FOH balcony / CAL01 checked Correction: Automatic COR01 correction applied; display represents R19694.8Operators: Kim monitors and logs LOG01; Park stands by to adjust output Action and recheck: Kim checked 94.8 in LOG01 at 19:45 and continued monitoringEntry earplugs with use instructions and lobby quiet area available / LeeBelow fictional operating ceiling. Choi to receive full log by 20:45
Closeout / 2026-11-09 20:45 Programme P01 and layout L01 / show ended at 20:30R1 on layout L01Meter: SLM-01 at FOH balcony / CAL01 attached Correction: Keep correction record COR01 with original measurement log LOG0196—Operators: Operations lead Choi receives LOG01 from Kim Action and recheck: Choi compared the 19:30 intervention and 19:45 recheck records at 20:45Lee sent earplug information and quiet-area operation record to ChoiRecords received. Lee to archive documents by 2026-11-10 12:00

Blank template preview

This preview shows a few rows. The downloaded file contains 24 prepared rows.

Eight columns · scroll horizontally to view the complete blank worksheet.

Concert sound-level measurement and response log — blank worksheet
Stage, time, programme, audience layout and run-time sourceAudience reference measurement positionLong-term meter position, device, calibration and correction evidenceEvent operating ceiling (dB LAeq,15min)Rolling average at reference position (dB LAeq,15min)Monitoring and output adjustment, action and recheckEarplugs and quiet-area informationStatus, open check, owner and deadline
————————
————————
————————

Check your completed template

  • Reference and long-term meter positions, calibration status, correction decision and evidence are recorded.
  • The event operating ceiling reflects checked conditions; rolling readings, action and recheck times form a continuous record.
  • Audience information and the person receiving closeout records are named.

What to pass to the next person

The audio lead gives the original meter log, calibration and correction evidence, and intervention times to the operations lead, who retains the audience-information record alongside them.

Check before using this template

The fictional 96 dB operating ceiling and all readings are illustrations. This form does not calculate sound levels or corrections or certify legal compliance or hearing safety. CSV has no formulas or input validation.

Sources used to develop this template

EVENTODIT created this template using the working methods described in the public sources below. It is not an official form and has not been reviewed or approved by those organisations.